Thiết bị đo độ dày , hàm lượng lớp phủ chrome+3 , chrome+6 Model 2501XBT hãng CIANFLONE USA

Thiết bị đo độ dày lớp phủ chrome+3 , chrome+6 Model 2501XBT hãng CIANFLONE USA ngành tôn

Thiết bị đo độ dày lớp phủ chrome+3 , chrome+6 Model 2501XBT hãng CIANFLONE USA ngành tôn

Portaspec® for Multi-Element Sequential Analysis

Model 2501XBT

Portaspec for Multi-Element Sequential Analysis: Ti to U

Portaspec WDXRF is capable of performing multi-element sequential analysis in the range of Ti to U and is ideal for measuring coating weights of both chrome and titanium pretreatment.

The Bench Top Portaspec is similar to the original Model 2501 Portaspec X-Ray Spectrograph. It contains a rotating goniometer that allows the user to analyze up to five elements, preset sequentially one at a time. The elemental range is from element #22 Titanium to element #92 Uranium. An easy load two-position sample holder is an integral part of the instrument configured for analyzing liquids, powders, solids and thin films. Samples are changed at the open end of the holder allowing a sample to be analyzed while one is being loaded.

The Portaspec is operated by a PC Touchscreen Notebook Computer, complete with Windows®-based preinstalled Software.

Other Bench Top Portaspec versions available are Fixed Channel Single Element, Dual Element and Multi-element for sequential analysis.

 

 

 

Specifications:

  • Bragg Angle Range 13 to 98 degrees; Two Theta
  • Analyzing Crystal Lithium Fluoride (200)
  • Element Range Ka 22-47 (Ti to Ag)
  • Element Range La 56-92 (Ba to U)
  • Collimators 20 mil Divergent (Source)
  • 10 mil Receiving (Detector)
  • X-ray Source X-Ray Tube, Tungsten Target, Beryllium Window
  • X-ray Tube Voltage 30 kV Constant Potential
  • X-ray Tube Voltage Regulation plus/minus 1% for plus/minus 10% line voltage variation
  • X-ray Tube Current 0 to 5 mA – Adjustable
  • Detector Tube Sealed Proportional
  • Detector Supply 2700 VDC Max. (Adjustable)
  • Digital Scaler and Timer-Integrated Counting Range: 1 to 999,999
  • Timer Range: 1 to 990 seconds
  • Lamps X-Ray On
  • Voltage Requirements 115 Volts AC, 50 or 60 Hertz 230 Volts AC, 50 or 60 Hertz
  • Single Phase, 300 watts
  • Line Regulation Required ± 5%
  • Dimensions and Weight 18″ Long, 14″ Wide, 13″ High, 56 lbs.

Included Items:

  • Electric Water Coolant and Circulator
  • Windows®-based Touch-screen Notebook Computer
  • PC Interface and Preinstalled Software

Related Products:

Thiết bị đo độ dày lớp phủ chrome+3 , chrome+6 Model 2501XBT hãng CIANFLONE USA ngành tôn

Portaspec® for Multi-Element Sequential Analysis

Model 2501XBT

Portaspec for Multi-Element Sequential Analysis: Ti to U

Portaspec WDXRF is capable of performing multi-element sequential analysis in the range of Ti to U and is ideal for measuring coating weights of both chrome and titanium pretreatment.

The Bench Top Portaspec is similar to the original Model 2501 Portaspec X-Ray Spectrograph. It contains a rotating goniometer that allows the user to analyze up to five elements, preset sequentially one at a time. The elemental range is from element #22 Titanium to element #92 Uranium. An easy load two-position sample holder is an integral part of the instrument configured for analyzing liquids, powders, solids and thin films. Samples are changed at the open end of the holder allowing a sample to be analyzed while one is being loaded.

The Portaspec is operated by a PC Touchscreen Notebook Computer, complete with Windows®-based preinstalled Software.

Other Bench Top Portaspec versions available are Fixed Channel Single Element, Dual Element and Multi-element for sequential analysis.

 

 

 

Specifications:

  • Bragg Angle Range 13 to 98 degrees; Two Theta
  • Analyzing Crystal Lithium Fluoride (200)
  • Element Range Ka 22-47 (Ti to Ag)
  • Element Range La 56-92 (Ba to U)
  • Collimators 20 mil Divergent (Source)
  • 10 mil Receiving (Detector)
  • X-ray Source X-Ray Tube, Tungsten Target, Beryllium Window
  • X-ray Tube Voltage 30 kV Constant Potential
  • X-ray Tube Voltage Regulation plus/minus 1% for plus/minus 10% line voltage variation
  • X-ray Tube Current 0 to 5 mA – Adjustable
  • Detector Tube Sealed Proportional
  • Detector Supply 2700 VDC Max. (Adjustable)
  • Digital Scaler and Timer-Integrated Counting Range: 1 to 999,999
  • Timer Range: 1 to 990 seconds
  • Lamps X-Ray On
  • Voltage Requirements 115 Volts AC, 50 or 60 Hertz 230 Volts AC, 50 or 60 Hertz
  • Single Phase, 300 watts
  • Line Regulation Required ± 5%
  • Dimensions and Weight 18″ Long, 14″ Wide, 13″ High, 56 lbs.

Included Items:

  • Electric Water Coolant and Circulator
  • Windows®-based Touch-screen Notebook Computer
  • PC Interface and Preinstalled Software