Thiết Bị Hãng STEP Lab
Thiết Bị Hãng STEP Lab

Hệ Thống Thử Nghiệm Kéo Dọc Trục Kết Hợp Mô Men Xoắn STEP Lab Model BV230

Axial Torsion Systems
Model: Axial Torsion Systems BV230

Axial Torsion Systems is the best solution for tensile and torsion testing. BV230 systems are available in a wide range of loads, with torque capacities up to 230 Nm, the compact design requires minimal space and offers a high level of rigidity and alignment. The torsional motor is coupled to every linear actuator series we manufacture, from electromechanical actuators, EA series and all UD, HUD and XUD series based on linear motors.

Liên hệ

Tổng quan

Hệ Thống Thử Nghiệm Kéo Dọc Trục Kết Hợp Mô Men Xoắn (Axial Torsion Systems) STEP Lab Model BV230


Certified Standards BV230

Plastics

PROOF MATERIAL NORMA DESCRIPTION
Static tests Plastic ASTM D638 Tensile properties of plastics
Static tests Plastic ISO 527-1
ISO 527-2
Plastics-Determination of Tensile Properties

Metal

PROOF MATERIAL NORMA DESCRIPTION
Static tests Metal ASTM E21 High-temperature tensile testing of metallic materials
Static tests Metal ASTM E290 Material bending test for ductility
Static tests Metal ASTM E517 Plastic deformation ratio r for sheet metal
Static tests Metal ASTM E646 Tensile hardening exponents (n-values) of sheet metal materials
Static tests Metal ASTM E8M Tensile testing of metallic materials
Static tests Metal ASTM E9 Compression testing of metallic materials at room temperature
Static tests Metal EN 10002-1:2001 (replaced by ISO EN 6892-1:2019) Tensile testing of metallic materials. Test method at room temperature
Static tests Metal ISO 6892-1 Metallic materials – Tensile testing Part 1: Test method at room temperature
Static tests Metal ISO 7438 Metallic materials. Proof of folding.
Static tests Metal ISO 783 Metallic materials – Tensile test of steel at high temperature

Bikes

PROOF MATERIAL NORMA DESCRIPTION
Static / Fatigue Bikes EN 15194 Electrically assisted pedal cycles – EPAC Bicycles – test methods
Static / Fatigue Bikes ISO 4210-3 Bicycle safety requirements – Part 3: Common test methods
Static / Fatigue Bikes ISO 4210-4 Safety requirements for bicycles – Part 4: Braking test methods
Static / Fatigue Bikes ISO 4210-5 Bicycle safety requirements – Part 5: Steering test methods
Static / Fatigue Bikes ISO 4210-6 Safety requirements for bicycles – Part 6: Test methods for frame and fork
Static / Fatigue Bikes ISO 4210-7 Bicycle safety requirements – Part 7: Test methods for wheels and rims
Static / Fatigue Bikes ISO 4210-8 Safety requirements for bicycles – Part 8: Pedal and drive system test methods
Static / Fatigue Bikes ISO 4210-9 Bicycle safety requirements – Part 9: Test methods for saddles and seatposts

Biomedical

PROOF MATERIAL NORMA DESCRIPTION
Static / Fatigue Biomedical ASTM F1264 Standard Specifications and Test Methods for Intramedullary Fixation Devices
Static / Fatigue Biomedical ASTM F1717 Standard test methods for spinal implant structures in a vertebrectomy model
Static / Fatigue Biomedical ASTM F1798 Standard test method for the evaluation of static and fatigue properties of interconnection mechanisms and subassemblies used in spinal arthrodesis implants
Static / Fatigue Biomedical ASTM F1800 Standard Practice for Cyclic Fatigue Testing of Metal Components of the Tibial Plateau of Total Knee Joint Prostheses
Static / Fatigue Biomedical ASTM F2068 Standard specifications for femoral prostheses – metal implants
Static / Fatigue Biomedical ASTM F2077 Test methods for intervertebral body fusion devices
Static / Fatigue Biomedical ASTM F2193 Standard specifications and test methods for components used in surgical fixation of the spinal skeletal system
Static / Fatigue Biomedical ASTM F2502 Standard specifications and test methods for resorbable plates and screws for internal fixation implants
Static / Fatigue Biomedical ASTM F2580 Standard practice for evaluating the modular connection of a proximally fixed femoral hip prosthesis
Static / Fatigue Biomedical ASTM F2706 Standard test methods for occipito-cervical and occipito-cervical-thoracic spinal implant constructions in a vertebrectomy model
Static / Fatigue Biomedical ASTM F382 Standard Specifications and Test Method for Metal Bone Plates
Static / Fatigue Biomedical ASTM F384 Standard specifications and test methods for angled metal devices for orthopaedic fracture fixation
Static / Fatigue Biomedical ASTM F543 Standard Specifications and Test Methods for Metal Medical Bone Screws
Static / Fatigue Biomedical EN 843-1 Mechanical properties of monolithic ceramics at room temperature – Determination of flexural strength
Static / Fatigue Biomedical ISO 11405 Tooth structure adhesion test
Static / Fatigue Biomedical ISO 12189-8 Mechanical testing of implantable spinal devices – Fatigue test method for spinal implant assemblies using anterior support
Static / Fatigue Biomedical ISO 14801 Dentistry – Implants – Dynamic load test for endosseous dental implants
Static / Fatigue Biomedical ISO 14879-1 Total knee joint replacement Determining the strength properties of tibial knee trays
Static / Fatigue Biomedical ISO 6872 Dentistry – Ceramic materials
Static / Fatigue Biomedical ISO 7206 Surgical implants – Partial and total hip joint replacements
Static / Fatigue Biomedical ISO 9585 Surgical implants – Determination of flexural strength and stiffness of bone plates

Rubber

PROOF MATERIAL NORMA DESCRIPTION
Static tests Rubber ISO 2439 Determination of hardness (indentation technique)
Static tests Rubber ISO 3386 Determination of stress-strain characteristics in compression

 

Hãy liên hệ với Năng Lực Company ngay để được tư vấn chuyên sâu và nhận các ưu đãi hấp dẫn nhất thông qua hotline/zalo: 0976.299.749!

Thông số kỹ thuật

BV SERIES BV020 BV035 BV060 BV080 BV100 BV170 BV230
Continuos torque 15 Nm 25 Nm 45 Nm 55 Nm 80 Nm 135 Nm 160 Nm
Dynamic torque (sinusoidal fatigue) 20 Nm 35 Nm 60 Nm 80 Nm 100 Nm 170 Nm 230 Nm
Test speed 350 rpm 350 rpm 200 rpm 150 rpm 200 rpm 200 rpm 100 rpm
Static axial load (max. admissible) * 15 kN 50 kN 50 kN 50 kN 50 kN 50 kN 50 kN
Dynamic axial load (max. admissible) * 10.5 kN 35 kN 35 kN 35 kN 35 kN 35 kN 35 kN
Cooling Air Air Air Air Water closed circuit Water closed circuit Water closed circuit
Max. number of revolutions ±10000 *
Rotational absolute encoder Integrated

* Higher values on request

CÔNG TY THIẾT BỊ CÔNG NGHỆ NĂNG LỰC

Địa chỉ: Số 1A, Đường Võ Thành Trang, Phường Bảy Hiền, TP.HCM
Hotline: 02.866.848.638
SĐT – ZALO: 0976.299.749 – zalo (Mr Tuấn, Giám Đốc Kinh Doanh)
Email: tuannguyen@nangluc.vn